Add this suggestion to a batch that can be applied as a single commit. This suggestion is invalid because no changes were made to the code. Suggestions cannot be applied while the pull request is closed. Suggestions cannot be applied while viewing a subset of changes. Only one suggestion per line can be applied in a batch. Add this suggestion to a batch that can be applied as a single commit. Applying suggestions on deleted lines is not supported. You must change the existing code in this line in order to create a valid suggestion. Outdated suggestions cannot be applied. This suggestion has been applied or marked resolved. Suggestions cannot be applied from pending reviews. Suggestions cannot be applied on multi-line comments. Suggestions cannot be applied while the pull request is queued to merge. Suggestion cannot be applied right now. Please check back later.
Sorry, @me-no-dev, I thought we'd hammered out the issues in the SSO conversion, but there's one more but just found.
As found by @mongozmaki in esp8266/Arduino#6035
With SSO implementation in String, StreamString::write generates wrong
strings under some circumstances. Reason is that String::len() returns
strlen(sso_buf) if SSO=true but with newly written data
(in StreamString::write) the null-termination missing at the time len()
is called.
Furthermore, len() is called twice which is inefficient if SSO=true.