Bug #13644: Windows - Setting Time.now

Added by MSP-Greg (Greg L) over 8 years ago. Updated about 2 years ago.

Status:
Closed
Assignee:
-
Target version:
-
ruby -v:
ruby 2.5.0dev (2017-06-04 trunk 59013) [x64-mingw32]
[ruby-core:81625]
Tags:

Description

While reviewing a MinGW build test-all failure in TestLogDevice#test_shifting_midnight_exist_file, I determined the cause. The test in question (and other tests that seem to have newer/better exception handling) sets Time.now.

The thread StackOverflow - Change system date programmatically seems to imply that in some instances/configurations, changing the system time on Windows systems requires elevated permissions.

I tested on both a mswin build (ruby 2.5.0dev (2017-05-27 trunk 58922) [x64-mswin64_140]) and a MinGW build (ruby 2.5.0dev (2017-06-08 trunk 59046) [x64-mingw32]), and both responded to:

Time.now = Time.mktime(2017, 1, 3, 1, 1, 1) 

with the following eror:

undefined method `now=' for Time:Class (NoMethodError) 

Both also had false = Time.respond_to?(:now=).

So, I'm confused as to how this test passes on mswin. Regardless, the test requires a skip to bypass it and allow MinGW test-all to pass.

I thought I'd file an issue before doing a PR. I'm building and testing on Win7. Finally, if anyone has time, where is the method now= defined?


Files

test-logger-test_logdevice.rb.patch (3.6 KB) test-logger-test_logdevice.rb.patch test/logger/test_logdevice.rb patch file MSP-Greg (Greg L), 06/11/2017 03:43 AM

Updated by MSP-Greg (Greg L) over 8 years ago Actions #1 [ruby-core:81644]

  • ruby -v set to ruby 2.5.0dev (2017-06-04 trunk 59013) [x64-mingw32]

Submitted PR #1645

Re tests, this PR changes a file used in test-all, which passes on both appveyor and travis.

Spec tests failed on appveyor with a failure that I have intermittently seen on MinGW builds.

Updated by nobu (Nobuyoshi Nakada) over 8 years ago Actions #2 [ruby-core:81647]

It's defined in FakeTime module which is prepended to Time.
I haven't seen that failure on mingw.

Updated by MSP-Greg (Greg L) over 8 years ago Actions #3 [ruby-core:81648]

Nobuyoshi,

It's defined in FakeTime module which is prepended to Time.

Thank you for being so polite and taking the time to respond. That was a very dumb mistake on my part. I reached that conclusion when I was fighting a poor, old, MinGW embedded ruby 2.2.4 build in a commercial app. It was nice when I swapped in my build of 2.3 stable, and everything worked...

Anyway, I believe I've found the real issue. It may be occurring because I'm using Win7, or possibly because I have UAC enabled.

On my system, File.utime only sets atime, not mtime. I suspect that the OS may not allow setting mtime. As you probably know, LogDevice.new uses mtime to determine whether it's time to create a new log file.

Normally, I can't see how that would be an issue, but re this test trying to mock things, it is.

If you have a minute, could you check the following code? For a MinGW build, it changes LogDevice to use atime to determine whether to create a new log.

require 'logger' module PLogDevice def initialize(log = nil, shift_age: nil, shift_size: nil, shift_period_suffix: nil) @dev = @filename = @shift_age = @shift_size = @shift_period_suffix = nil mon_initialize set_dev(log) if @filename @shift_age = shift_age || 7 @shift_size = shift_size || 1048576 @shift_period_suffix = shift_period_suffix || '%Y%m%d' unless @shift_age.is_a?(Integer) base_time = @dev.respond_to?(:stat) ? (RUBY_PLATFORM !~ /mingw/ ? @dev.stat.mtime : @dev.stat.atime) : # @dev.stat.mtime : Time.now @next_rotate_time = next_rotate_time(base_time, @shift_age) end end end end class Logger::LogDevice ; prepend PLogDevice ; end module FakeTime ; attr_accessor :now ; end class << Time ; prepend FakeTime ; end log = "log" File.open(log, "w") {} File.utime(*[Time.mktime(2014, 1, 2, 0, 0, 0)]*2, log) Time.now = Time.mktime(2014, 1, 2, 23, 59, 59, 999000) dev = Logger::LogDevice.new(log, shift_age: 'daily') dev.write("#{Time.now} hello-1\n") dev.close puts "\nTime.now #{Time.now}\n" \ "atime #{File.atime(log)}\n" \ "mtime #{File.mtime(log)}\n" Time.now = Time.mktime(2014, 1, 3, 1, 1, 1) dev = Logger::LogDevice.new(log, shift_age: 'daily') dev.write("#{Time.now} hello-2\n") dev.close puts "\nTime.now #{Time.now}\n" \ "atime #{File.atime(log)}\n" \ "mtime #{File.mtime(log)}\n" 

As listed, the logs are written correctly to the same folder the script is in. If you uncomment

# @dev.stat.mtime : 

and comment

 (RUBY_PLATFORM !~ /mingw/ ? @dev.stat.mtime : @dev.stat.atime) : 

it behaves as normal (using mtime) and will fail (appending to the log file, not creating another one).

Hence, I don't believe there's an issue with logger, it's an issue with trying to mock this.

If adding the prepend to LogDevice looks okay, someone should do a PR or commit.

Again, thanks for all your work, both Ruby in general and windows issues.

Updated by MSP-Greg (Greg L) over 8 years ago Actions #4 [ruby-core:81649]

nobu,

Attached is the patch I'm using in my MinGW build system for the test in question. It passes, and my test-all is now at 3 failures.

I ran into three issues with the current test mock.

  1. Once I patched logger to use atime, the test wouldn't pass if the FakeTime.now DST setting was different that the current system DST setting. So, I moved the mock FakeTime.now to today.
  2. Temp Directories using a block. I had issues with readline tests and temp files. With this, I could not get all the asserts to pass with a block. As to files, I believe Windows may have issues with - if process A does not close a file, process B can neither close nor delete the file.
  3. As I understand Logger, there was code that would not be used in a normal Logger application. Removed/changed code that opened the log file first, code that closed and then opened (with .new) the log file, etc.

The current test uses a midnight delta of -1mS and +01:01:01. The plus delta seems high, and from the GH 539, the author (megayu) states

In my real situation, if there is some events in 23:59:59, it will never shift the log file.

Seems to imply a minus delta of around a second. So, I set up the test with a symmetrical delta. I tested three deltas, 1000mS, 500mS, and 10mS, no failures with three processes running 50 tests each.

I can't test any other platform without pushing a PR. I learned a bit about the logger library.

Aside - found an interesting line in the file #729, just after the test in question.

env_tz_works = /linux|darwin|freebsd/ =~ RUBY_PLATFORM # borrow from test/ruby/test_time_tz.rb 

Updated by jeremyevans0 (Jeremy Evans) about 2 years ago Actions #5

  • Status changed from Open to Closed